logo
Harga yang bagus  on line

rincian produk

Created with Pixso. Rumah Created with Pixso. Produk Created with Pixso.
Penghalang Keamanan Pepperl Fuchs
Created with Pixso. Pepperl Fuchs HART MUX Modul sekunder KFD0-HMS-16 Tidak diperlukan daya eksternal

Pepperl Fuchs HART MUX Modul sekunder KFD0-HMS-16 Tidak diperlukan daya eksternal

Nama merek: PEPPERL FUCHS
Nomor Model: KFD0-HMS-16
MOQ: 1
Harga: negotiable
Waktu Pengiriman: dapat dinegosiasikan
Ketentuan Pembayaran: T/T
Informasi Rinci
Tempat asal:
JERMAN
Manufacturer:
PEPPERL FUCHS
Nomor produk:
KFD0-HMS-16
Safety Integrity Level (SIL):
SIL 3
Fieldbus Standard:
IEC 61158-2
Ambient temperature:
-20 ... 65 °C (-4 ... 149 °F)
Perumahan:
Lihat Gambar 1
Degree of protection:
IP20
Mass:
approx. 100 g
Kemasan rincian:
Kotak
Menyediakan kemampuan:
100pcs per bulan
Menyoroti:

HART MUX Secondary Module

,

HART MUX Secondary Module KFD0-HMS-16

,

KFD0-HMS-16

Deskripsi Produk

Pepperl Fuchs HART MUX Modul sekunder KFD0-HMS-16

16 saluran

Tidak diperlukan daya eksternal

Masukan perangkat lapangan HART (revisi 5 sampai 7)

Digunakan dengan modul utama HART MUX KFD2-HMM-16

Hingga SIL 3 sesuai dengan IEC/EN 61508

Spesifikasi umum

Modul sekunder HART MUX

Parameter yang berkaitan dengan keselamatan fungsional

Tingkat Integritas Keamanan (SIL) SIL 3

Pasokan

Koneksi melalui kabel datar 14 saluran dari modul utama KFD2-HMM-16

Saluran sinyal HART (tidak aman secara intrinsik)

Kesesuaian input perangkat lapangan HART (revisi 5 sampai 7)

Sambungan kabel datar 26 pin untuk koneksi analog

Kabel datar 14 pin untuk koneksi modul primer/modul sekunder antara KFD2-HMM-16 dan KFD0-HMS-16

arus kebocoran < 3 μA pada -20... 85 °C (-4... 185 °F)

Resistor terminasi eksternal 230... 500 Ω standar (sampai 1000 Ω mungkin)

Tegangan output ≥ 400 mV ss (dengan resistensi terminator yang ditentukan di atas)

Resistensi output 100 Ω atau lebih kecil, kopling kapasitif

Impedansi masukan sesuai dengan spesifikasi HART

Kisaran tegangan input 0,08... 4 V ss; biasanya ± 5,2 V sebagai referensi lokal

Indikator/pengaturan

Ruang pelabelan untuk pelabelan di depan

Kesesuaian dengan Directive

Kompatibilitas elektromagnetik

Peraturan Direksi (EU) No 61326-1:2013

Kesesuaian

Tingkat perlindungan IEC 60529:2001

Kondisi lingkungan

Suhu lingkungan -20... 65 °C (-4... 149 °F)

Spesifikasi mekanik

Tingkat perlindungan IP20

Massa sekitar 100 g

Dimensi 20 x 93 x 115 mm (0,8 x 3,7 x 4,5 inci) (W x H x D), tipe perumahan B1

Pemasangan pada rel pemasangan 35 mm DIN sesuai dengan EN 60715:2001

Data untuk aplikasi dalam hubungannya dengan daerah berbahaya

Sertifikat PF 07 CERT 1143

Penandaan Ex-Hexagon II 3G Ex nA IIC T4 Gc

Kesesuaian dengan Directive

Peraturan Menteri Keuangan    EN 60079-0:2012+A11:2013, EN 60079-15:2010

Pepperl Fuchs HART MUX Modul sekunder KFD0-HMS-16 Tidak diperlukan daya eksternal 0



Harga yang bagus  on line

rincian produk

Created with Pixso. Rumah Created with Pixso. Produk Created with Pixso.
Penghalang Keamanan Pepperl Fuchs
Created with Pixso. Pepperl Fuchs HART MUX Modul sekunder KFD0-HMS-16 Tidak diperlukan daya eksternal

Pepperl Fuchs HART MUX Modul sekunder KFD0-HMS-16 Tidak diperlukan daya eksternal

Nama merek: PEPPERL FUCHS
Nomor Model: KFD0-HMS-16
MOQ: 1
Harga: negotiable
Rincian kemasan: Kotak
Ketentuan Pembayaran: T/T
Informasi Rinci
Tempat asal:
JERMAN
Nama merek:
PEPPERL FUCHS
Nomor model:
KFD0-HMS-16
Manufacturer:
PEPPERL FUCHS
Nomor produk:
KFD0-HMS-16
Safety Integrity Level (SIL):
SIL 3
Fieldbus Standard:
IEC 61158-2
Ambient temperature:
-20 ... 65 °C (-4 ... 149 °F)
Perumahan:
Lihat Gambar 1
Degree of protection:
IP20
Mass:
approx. 100 g
Kuantitas min Order:
1
Harga:
negotiable
Kemasan rincian:
Kotak
Waktu pengiriman:
dapat dinegosiasikan
Syarat-syarat pembayaran:
T/T
Menyediakan kemampuan:
100pcs per bulan
Menyoroti:

HART MUX Secondary Module

,

HART MUX Secondary Module KFD0-HMS-16

,

KFD0-HMS-16

Deskripsi Produk

Pepperl Fuchs HART MUX Modul sekunder KFD0-HMS-16

16 saluran

Tidak diperlukan daya eksternal

Masukan perangkat lapangan HART (revisi 5 sampai 7)

Digunakan dengan modul utama HART MUX KFD2-HMM-16

Hingga SIL 3 sesuai dengan IEC/EN 61508

Spesifikasi umum

Modul sekunder HART MUX

Parameter yang berkaitan dengan keselamatan fungsional

Tingkat Integritas Keamanan (SIL) SIL 3

Pasokan

Koneksi melalui kabel datar 14 saluran dari modul utama KFD2-HMM-16

Saluran sinyal HART (tidak aman secara intrinsik)

Kesesuaian input perangkat lapangan HART (revisi 5 sampai 7)

Sambungan kabel datar 26 pin untuk koneksi analog

Kabel datar 14 pin untuk koneksi modul primer/modul sekunder antara KFD2-HMM-16 dan KFD0-HMS-16

arus kebocoran < 3 μA pada -20... 85 °C (-4... 185 °F)

Resistor terminasi eksternal 230... 500 Ω standar (sampai 1000 Ω mungkin)

Tegangan output ≥ 400 mV ss (dengan resistensi terminator yang ditentukan di atas)

Resistensi output 100 Ω atau lebih kecil, kopling kapasitif

Impedansi masukan sesuai dengan spesifikasi HART

Kisaran tegangan input 0,08... 4 V ss; biasanya ± 5,2 V sebagai referensi lokal

Indikator/pengaturan

Ruang pelabelan untuk pelabelan di depan

Kesesuaian dengan Directive

Kompatibilitas elektromagnetik

Peraturan Direksi (EU) No 61326-1:2013

Kesesuaian

Tingkat perlindungan IEC 60529:2001

Kondisi lingkungan

Suhu lingkungan -20... 65 °C (-4... 149 °F)

Spesifikasi mekanik

Tingkat perlindungan IP20

Massa sekitar 100 g

Dimensi 20 x 93 x 115 mm (0,8 x 3,7 x 4,5 inci) (W x H x D), tipe perumahan B1

Pemasangan pada rel pemasangan 35 mm DIN sesuai dengan EN 60715:2001

Data untuk aplikasi dalam hubungannya dengan daerah berbahaya

Sertifikat PF 07 CERT 1143

Penandaan Ex-Hexagon II 3G Ex nA IIC T4 Gc

Kesesuaian dengan Directive

Peraturan Menteri Keuangan    EN 60079-0:2012+A11:2013, EN 60079-15:2010

Pepperl Fuchs HART MUX Modul sekunder KFD0-HMS-16 Tidak diperlukan daya eksternal 0